    AL-34WB 10A - Standard Electric Works Co., Ltd

    ● Wire length: 1m approx.    Silicone insulated wire (700mm) with wire connected to straight input plugs (150mm PVC wire), and wire for clamp (150mm PVC wire).● Outside diameter of silicone insulated wire: 6.4mm   Outside diameter of PVC wire: 4mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 10A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Test Leads

    AL-34WB - Standard Electric Works Co., Ltd

    ● Wire length: 1.2m approx.    Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm   Outside diameter of  PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • IGBT Drive

    Renesas Electronics Corp.

    IGBT gate drive photocouplers (optocouplers) are optically coupled isolators containing a GaAlAs LED on the input side and a photo diode, signal processing circuit and power output transistor on the output side in a single chip. This coupler is designed specifically to provide high common mode transient immunity (CMR) and a high output current, and has an active miller clamp and high switching speed, making it ideal for driving IGBTs and MOS FETs.

  • Transmission Line Testers

    GAO Tek Inc.

    GAOTek provides affordable, safe and reliable transmission line testers, digital clamp meters and power meters for sale to the United States, Canada and Globally. A transmission line is a specialized cable designed to conduct alternative current of radio frequency. Transmission lines are used for connecting radio transmitters and receivers with their antenna to distribute signals.

  • Cable Identification & Phasing

    VCi-3™ - ndb Technologies Inc.

    The VCi-3™ system is designed for cable and phase identification, mainly for instal­lation or maintenance purposes on three-phase electrical networks during power shutdowns.The transmitter module injects a low current on the cable conductors by direct con­tact or magnetic clamps methods. A voice message is recorded by the user and will be transmitted along with digital signals. Groundings stay connected at both ends of the three-phase circuit during the test. The detector module is used at the other end of the cable system.

  • 1-/3-Phase 1000A True RMS AC Power Clamp Meter

    Extech PQ2071 - Extech Instruments Corporation

    The PQ2071 is a 1-/3-Phase 1000 Amp True RMS AC Power Clamp Meter. Extech's multifunctional PQ2071 Power Clamp meter operates as a True RMS Clamp Meter, Power Meter, Multimeter, and AC Voltage Detector. Featuring a CAT IV-600 Volt safety rating, the PQ2071 measures AC Current, Voltage, Frequency and Power including True Power, Apparent Power, Reactive Power and Active Power. Measures 1-Phase and balanced 3-Phase True Power (kW), Apparent Power (kVA), Reactive Power (kVAR) and Active Power (kWh), plus Power Factor and Phase Angle. Featuring a 2.16 in. (55 mm) clamp jaw opening. Large dual backlit LCD display (9999 count) with bargraph. Frequency measurements to 200Hz. manually store/recall up to 99 data sets. Data Hold, Max/Min, and Auto power off functions. USB interface for connection to a PC for data logging function with included software. Complete with test leads, four color-coded leads and alligator clips, USB cable, PC software, 9V battery and soft case.

  • Flexible Clamp Meter 18 inch

    FLIR CM57 - Teledyne FLIR

    The FLIR CM57 is an ergonomic tool designed to simplify difficult current measurements. Made with a narrow, 18-inch (45.72 cm) flexible coil clamp, the CM57 lets you easily take measurements in tight or awkward spots. It is ideal for multiple-conductor measurements and double-wrap requirements. With Bluetooth® communication for remote viewing and data transfer to iOS® and Android™ devices via the FLIR Tools Mobile app, you can analyze and share data fast right from the jobsite.

  • TRMS AC/DC Clamp-on Power

    HT9023 - HT Italia Srl

    HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems.

  • 2000A True RMS AC/DC Clamp Meter

    Extech 380926 - Extech Instruments Corporation

    The 380926 is a category IV, 2000-Amp, TRMS AC/DC Clamp Meter which has a rugged 2 in. jaw that accommodates two 500MCM cables. A built-in full-function DMM can measure AC/DC Voltage and Current, Resistance, capacitance, frequency, Duty Cycle, Diode and Continuity. Measurements are displayed on the large 4000 count backlit display for easy viewing in dimly lit areas. Additional features include DCA push button zero, Data Hold, and Relative function. Complete with test leads and 9V battery.

  • Clamp Meters

    Nanjing ELIKE Meter Co, Ltd.

    Basic functions:AC current: 40/400/1000ADC current: 40/400/1000AAC voltage: 4/40/400/750VDC voltage: 400mV/4/40/400/1000VResistor: 400/4/40/400K/4/40MTemperature: -20 to +750°CFrequency: 10/100/1000Hz/10/100kHz/10MHzDuty cycle: 0.1 to 99.9%Capacitance: 5nF/50nF/500nF/5μF/50μF/200μFSpecial functions:Auto rangingNCVDiodeContinuity buzzerLow battery displayData holdRelative data holdAuto/manual range shiftZeroAuto power-offOverload protectionSampling frequency: 3 times/sMaximum display: 3999Maximum open distance of clamp mouth: 55mmGeneral characteristics:Color: iron gray and orangeNet weight: approximately 274gLCD size: 46 x 32mmSize: 245 x 90 x 33mmPower: 1 x 9V and 6F22Packing content:CartonHandheld bagEnglish manualTesting leadBatteryTemperature probe

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.

  • Riverboat SP

    Teledyne Marine RD Instruments

    The Riverboat SP is the top choice for deployment of the Teledyne RDI StreamPro acoustic Doppler current profiler. Upgrade from the standard StreamPro float to the more stable, rugged and fully corrosion-resistant tethered boat. The Riverboat SP makes safe, easy measurements of discharge in relatively slow and fast flowing waters. Made of unbreakable polyethylene, the Riverboat SP is strong and can handle tough deployment conditions. The standard boat configuration fits a TRDI StreamPro ADCP, and the latest instrument clamp is suitable for the StreamPro with or without an internal compass upgrade.

  • Portable Electricity Meter Testers

    EE-120A-3S - EMSYST Ltd

    The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.

  • 600A AC Clamp Meter + NCV

    Extech MA610 - Extech Instruments Corporation

    The MA610 is a fully loaded clamp meter with multimeter functions including AC Current, AC/DC Voltage, Resistance, Frequency, and Capacitance. It also has a built-in non-contact voltage (NCV) detector to quickly check circuits and wires for live voltages. It’s a pocket-sized meter with 1.2" (30mm) jaw that fits conductors up to 500MCM and is designed with a large backlit LCD display to view in dimly lit area.

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.